Skip to content

B2B & Commercial Projects Only

FOB / CIF Quotations

ENIS中文Get a Quote

Hotel / resort · Multifamily · Serviced apartment

An access project delivered as one configurable system

A project order is not a lock list. ENIS assembles the guestroom lock, the card system, the elevator control, the issuing equipment and the room-by-room delivery into one engineering package, documented against your door schedule, your property management system and your installation programme.

Hotel guestroom entrance door with a black smart lock and lever handle

Two delivery scenarios

Hotel and multifamily programmes run on different rules

The scenario decides the configuration package, the delivery method and what we need from you before the quotation is issued.

Hotel room door edge with a lever handle and cylinder set

Hotel / resort

One-card hospitality with PMS linkage

Supply scope: guestroom locks on the ANSI 7098 five-latch panic mortise, TCP/IP encoders, card issuing machines, handheld terminals and elevator controllers. Core specification: 13.56MHz Mifare-1 encrypted cards with 2³² key combinations, 4 × AA alkaline power and 15,000+ cycles. Delivery: numbered door sets and card stock shipped against the room schedule, with the encoder and middleware scope confirmed before shipment. We need from you: the PMS name and version, the room-type and room-number list, the door schedule and the destination port.

See the technical scope →

Black keypad and fingerprint smart lock on a modern apartment entrance wall

Multifamily / serviced apartment

Bulk room management across a block or a portfolio

Supply scope: apartment and guestroom locks on the 62-series mortise platform, self check-in card issuing, building entrance and common-area access control. Core specification: one mortise, spindle and cylinder across hotel and apartment doors, so a single spare-parts pool covers the property. Delivery: locks and door sets labelled by floor and room number and packed for room-by-room installation. We need from you: the unit and door schedule, the credential policy per door group, the app or platform decision and the destination port.

See the technical scope →

Standards and interfaces the range is documented against

The matrix below lists the standards and interfaces covered by the ENIS access control range. The test evidence and declarations are issued against the project brief and the tested assembly, so the documents match the doors and the software actually being supplied.

Standard or interfaceWhat it coversProject note
EN 12209Electromechanical lock standard covering the mortise and lock setDeclaration and test report issued against the project brief
EN 14846Fire-resistance classification of the lock within a tested assemblyRated per project against the tested assembly
UL 10CPositive-pressure fire test of the lock bodyTest document issued with the model documentation set
Opera PMSCard write and event push through the encoder WebAPIInterface confirmed against your PMS instance and room-type map
EN 1634-1Fire door assembly test for the complete door setIssued against the project brief for the specified assembly

Elevator controller and issuing device selection

The elevator controller is chosen from the number of floors served and from the way the guest calls the car. The issuing equipment is sized from the room count. Elevator controller supply excludes on-site installation, which is carried out by your lift contractor.

ModelFunctionSelection note
ZF-EC01-8FElevator controller for buildings with 8 floors or fewerManual mode — the guest selects the floor
ZF-EC01-16FElevator controller for buildings with 16 floors or fewerManual mode — the guest selects the floor
ZF-EC01-16FElevator controller, 16-floor direct arrivalAutomatic mode — the card returns the authorised floor
ZF-MFC01-16Card issuing machine — reads and writes card informationCatalogue recommendation: two units per hotel
ZF-PHD01-16Handheld terminal — room numbers, lock time, opening records, automatic check-in and check-out, lock status checkCarried by maintenance staff on site
ZF-MJ01-ASingle-door access controlCommon, service and back-of-house doors
ZF-EC01 seriesRelay configuration and working voltageIssued against the project brief

Bulk project organisation

How a multi-room programme is structured

The card hierarchy, the network and the audit trail are agreed before production, because they decide how the building is operated rather than how the lock is built.

Card hierarchy

  • Guestroom opening card — issued per room and per stay
  • Master card — building-wide access held by management
  • Building card — access to one block or tower
  • Floor card — access to a single floor
  • Multi-door card — one credential across several doors

Network and records

  • Client machine and server connected over TCP/IP
  • Card data read and written automatically at the issuing machine
  • Opening records retained on the lock and exported through the encoder
  • TT-Lock and Tuya platforms available for the management layer

Issuing equipment

  • Card issuing machine handles the card data end to end
  • Two issuing machines per hotel on the catalogue recommendation
  • For a 500-room property the catalogue recommends more than five issuing machines in service
  • Handheld terminal for room numbers, lock time and opening records on site

Delivery and labelling

  • Locks and door sets labelled by floor and room number
  • Sets cased for room-by-room installation
  • Container loading plan built from the room schedule
  • Shipment documents issued with the packing list

How a project order runs

  1. 1

    Brief review

    The door schedule, room numbers, PMS name, required standards and destination port are read back to you with the open points listed.

  2. 2

    Configuration package

    Model, mortise, card hierarchy, encoder quantity, elevator controller and issuing equipment are set out against the brief.

  3. 3

    Approval and documentation

    Dimension drawings, cut-out positions and the documentation set are issued for your review before production starts.

  4. 4

    Production and shipment

    Locks are produced, inspected, labelled by room number and loaded against the container plan.

Submit a project brief

A brief with the door schedule, the room count, the property management system and the delivery port is enough for us to return a configuration package with a formal quotation.

We reply within one business day. .

Send us the door schedule and the room numbers

Our engineering team replies within one business day with the configuration package, the documentation list and a formal quotation.